S-800 Equipment Overview
Actual reflow-oven and conveyor reference footage.
Standalone HTML: all page images and six web-optimised reference videos are embedded in this one file for direct upload.
Start from the S, SR or SA product family, then open the dedicated series page to review its detailed model table, rail route, cooling path and configuration options.
This overview page is intentionally short. Each card below is a separate customer-facing product page with its own detailed specifications table. It is easier for you to share a precise model-family link instead of sending a customer to one long mixed page.
8, 10 and 12 zone model paths, with detailed dimensions, power, transport, cooling and nitrogen option tables.
Models: S-800, S-800D, S-1000, S-1000D, S-1200, S-1200DOpen S detailed parameters8, 10 and 12 zone series with SR-specific dimensions, cooling configuration, conveyor and optional nitrogen routes.
Models: SR-800, SR-800D, SR-1000, SR-1000D, SR-1200, SR-1200DOpen SR detailed parameters8 and 10 zone single-rail or dual-rail options, with a dedicated complete parameter table for the SA family.
Models: SA-800, SA-1000, SA-800D, SA-1000DOpen SA detailed parametersConfirm PCB width, thickness, component clearance and whether one or two rails are needed before selecting a model route.
Review solder paste, lead-free process, profile validation, cooling expectation and any nitrogen requirement.
Confirm target output, transport direction, upstream/downstream equipment, electrical supply and available installation space.
Use the separate technology centre for real equipment images, six supplied video clips, function routes and the technical-document test framework. This keeps the homepage simple while giving customers a proper detailed page to study.
View real reflow-oven, conveyor and production-line images from the supplied material folder.
Equipment overview, mesh belt, test area, conveyor demonstration and workshop footage are on one shareable page.
Review functions and the supplied thermal-evaluation method, then continue to the exact model table.
Each series has a different model range and parameter table. Separate pages avoid mixing dimensions, cooling-zone counts, rail widths and options from different product families.
In the supplied product material, D identifies the listed dual-rail versions. The final rail arrangement and usable board width must be confirmed for the project.
Yes. You can send the S, SR or SA page directly after you know the likely series. This is the intended use of the new site structure.
S-800, S-800D, S-1000, S-1000D, S-1200 and S-1200D. Select from 8, 10 or 12 upper/lower heating-zone model paths, then confirm conveyor, cooling, nitrogen and inspection options for the final production requirement.
The supplied S Series material lists single-rail and dual-rail configurations across the 800, 1000 and 1200 families. Heating-zone count, oven length, exterior dimensions, power, cooling and rail capability change by model. Use this table for initial selection; final scope must be confirmed in the quotation and technical agreement.
8, 10 or 12 upper and lower heating zones with a listed control range from room temperature to 300°C.
Single rail or D-model dual rail, chain + mesh transport for air reflow, and listed chain transport for nitrogen reflow.
Forced-air cooling is listed; water-chiller cooling is shown for nitrogen reflow configurations.
Open the Technology & Video Centre for supplied-equipment media and the technical evaluation route, then return here for S-series values.
All figures below are transcribed from the supplied S Series product table. The horizontal table can be scrolled on a phone.
| Parameter | S-800 | S-800D | S-1000 | S-1000D | S-1200 | S-1200D |
|---|---|---|---|---|---|---|
| Machine parameters | ||||||
| Dimensions (L × W × H) | 5825 × 1430 × 1530 mm | 5825 × 1680 × 1530 mm | 6605 × 1430 × 1530 mm | 6605 × 1680 × 1530 mm | 7355 × 1430 × 1530 mm | 7355 × 1680 × 1530 mm |
| Colour | Computer grey | |||||
| Approx. weight | 2830 kg | 3170 kg | 3270 kg | 3670 kg | 3720 kg | 4170 kg |
| Heating zones | 8 top / 8 bottom | 10 top / 10 bottom | 12 top / 12 bottom | |||
| Heating length | 3110 mm | 3890 mm | 4640 mm | |||
| Cooling zones | 4 top / 4 bottom | |||||
| Rectifying plate structure | Small circulation | |||||
| Exhaust volume requirement | 11 m³/min × 2 channels | 12 m³/min × 2 channels | ||||
| Control system | ||||||
| Power supply | 3 phase, 380 V, 50/60 Hz (option: 3 phase, 220 V, 50/60 Hz) | |||||
| Total power | 64 kW | 67 kW | 80 kW | 83 kW | 96 kW | 99 kW |
| Startup power | 30 kW | 32 kW | 36 kW | 38 kW | 42 kW | 44 kW |
| Normal power consumption | 9 kW | 10 kW | 10 kW | 11 kW | 11 kW | 12 kW |
| Warm-up time | Approx. 20 min | |||||
| Temperature control range | Room temperature to 300°C | |||||
| Temperature control method | PID closed-loop control + SSR drive (PC + PLC) | |||||
| Temperature control precision | ±1°C | |||||
| PCB temperature deviation | ±1.5°C (by RM board test standard) | |||||
| Data storage | Process data and status storage for multiple production settings | |||||
| Abnormal alarm | Abnormal temperature alarm (extra-high / extra-low temperature after constant temperature) | |||||
| Board dropped alarm | Signal light: yellow warm-up, green normal, red abnormal | |||||
| Conveyor system | ||||||
| Rail structure | Overall sectional type | |||||
| Chain structure | Double-buckle design for preventing board jamming | |||||
| Maximum PCB width | 400 mm (option: 460 mm) | Dual rail: 300 mm × 2 | ||||
| Rail-width adjustment range | 50-400 mm (option: 50-460 mm) | Dual rail: 300 mm × 2 | ||||
| Component clearance | Top 30 mm / bottom 30 mm | |||||
| Conveyor direction | Left to right (option: right to left) | |||||
| Fixed rail side | Front rail fixed (option: rear rail fixed) | |||||
| PCB conveyor method | Air reflow: chain + mesh. Nitrogen reflow: chain; mesh is listed as an option. | |||||
| Conveyor height | 900 ± 20 mm | |||||
| Conveyor speed | 300-2000 mm/min | |||||
| Auto-lubrication | Multi-lubricating mode can be selected; automatic or manual lubrication | |||||
| Cooling, process management and listed options | ||||||
| Cooling method | Forced-air cooling | Water-chiller cooling listed for nitrogen reflow | ||||
| KIC RPI Reflow Process Inspection System | Option listed in supplied material | |||||
| Nitrogen system (reserved) | N-suffix configuration listed with nitrogen sealed structure, pipe, N2 flow meter and water chiller | |||||
| Full nitrogen system | Listed with oxygen analyser (pipe type) added to the nitrogen-reserved equipment scope | |||||
| Nitrogen consumption | For standard 400 mm width: 300-1000 ppm O2, 10-20 m³/h; N2 consumption noted as 500-1000 ppm O2, 20-30 m³/h | |||||
| Central support | Option listed. Supplied material notes no mesh if the central-support system is selected. | |||||
| Dual-rail conveyor | D model: dual rail; front and rear rails fixed, two central adjustable PCB rails (listed width 300 mm × 2) | |||||
The PDF uses approximate dimensions and weights. Final equipment scope, local electrical conditions, nitrogen consumption, cooling, usable board envelope and acceptance criteria must be confirmed before quotation.
S-800 / S-800D, S-1000 / S-1000D and S-1200 / S-1200D are the six model designations in the supplied table.
D identifies the listed dual-rail model path. Confirm PCB size per rail and desired throughput before selecting it.
The supplied table lists N-suffix configurations for nitrogen-related reflow setups. Confirm oxygen target, process and gas installation scope before quotation.
The full table gives a technical starting point. It does not guarantee suitability for a particular PCB assembly or solder profile without project-specific validation.
Start with the required heating-zone length, board width, throughput, single/dual rail requirement, cooling requirement and any nitrogen process need. These inputs decide whether the 800, 1000 or 1200 family is appropriate.
No. The table is based on the supplied product material. The final quotation must reconfirm project-specific equipment, utility and acceptance conditions.
Yes. Share the current oven, PCB range, process, line interfaces and installation conditions so the configuration can be compared before a model is selected.
SR-800, SR-800D, SR-1000, SR-1000D, SR-1200 and SR-1200D. The SR family provides 8, 10 or 12 upper/lower heating-zone model paths with the SR-specific oven length, cooling and conveyor parameters below.
The supplied SR Series table separates the 800, 1000 and 1200 families, with both standard and D-model configurations. The series material records a small-circulation rectifying-plate structure and Alcoa gold nano hard oxidation material treatment. Confirm final equipment selection against the actual PCB, throughput and line conditions.
8, 10 or 12 upper/lower heating zones, room temperature to 300°C control range, PID closed loop and SSR drive are listed.
Single-rail and D-model dual-rail paths, sectional rails, anti-jam chain design and 300-2000 mm/min speed are listed.
Nitrogen-related configurations, water-chiller cooling for nitrogen reflow and KIC RPI process inspection are shown as options.
Open the Technology & Video Centre for supplied-equipment media and the technical evaluation route, then return here for SR-series values.
All figures below are transcribed from the supplied SR Series product table. The horizontal table can be scrolled on a phone.
| Parameter | SR-800 | SR-800D | SR-1000 | SR-1000D | SR-1200 | SR-1200D |
|---|---|---|---|---|---|---|
| Machine parameters | ||||||
| Dimensions (L × W × H) | 5520 × 1430 × 1530 mm | 5520 × 1680 × 1530 mm | 6300 × 1430 × 1530 mm | 6300 × 1680 × 1530 mm | 7050 × 1430 × 1530 mm | 7050 × 1680 × 1530 mm |
| Colour | Computer grey | |||||
| Approx. weight | 2710 kg | 2760 kg | 3020 kg | 3060 kg | 3310 kg | 3360 kg |
| Heating zones | 8 top / 8 bottom | 10 top / 10 bottom | 12 top / 12 bottom | |||
| Heating length | 3110 mm | 3892 mm | 4675 mm | |||
| Cooling zones | 3 top / 3 bottom | |||||
| Rectifying plate structure | Small circulation | |||||
| Rectifying plate material | Alcoa gold nano hard oxidation | |||||
| Exhaust volume requirement | 11 m³/min × 2 channels | 12 m³/min × 2 channels | ||||
| Control system | ||||||
| Power supply | 3 phase, 380 V, 50/60 Hz (option: 3 phase, 220 V, 50/60 Hz) | |||||
| Total power | 64 kW | 67 kW | 80 kW | 83 kW | 96 kW | 99 kW |
| Startup power | 30 kW | 32 kW | 36 kW | 38 kW | 42 kW | 44 kW |
| Normal power consumption | 9 kW | 10 kW | 10 kW | 11 kW | 11 kW | 12 kW |
| Warm-up time | Approx. 20 min | |||||
| Temperature control range | Room temperature to 300°C | |||||
| Temperature control method | PID closed-loop control + SSR drive (PC + PLC) | |||||
| Temperature control precision | ±1°C | |||||
| PCB temperature deviation | ±1.5°C (by RM board test standard) | |||||
| Data storage | Process data and status storage for multiple production settings | |||||
| Abnormal alarm | Abnormal temperature alarm (extra-high / extra-low temperature after constant temperature) | |||||
| Board dropped alarm | Signal light: yellow warm-up, green normal, red abnormal | |||||
| Conveyor system | ||||||
| Rail structure | Overall sectional type | |||||
| Chain structure | Double-buckle design for preventing board jamming | |||||
| Maximum PCB width | 400 mm (option: 460 mm) | Dual rail: 300 mm × 2 | ||||
| Rail-width adjustment range | 50-400 mm (option: 50-460 mm) | Dual rail: 300 mm × 2 | ||||
| Component clearance | Top 30 mm / bottom 30 mm | |||||
| Conveyor direction | Left to right (option: right to left) | |||||
| Fixed rail side | Front rail fixed (option: rear rail fixed) | |||||
| PCB conveyor method | Air reflow: chain + mesh. Nitrogen reflow: chain; mesh is listed as an option. | |||||
| Conveyor height | 900 ± 20 mm | |||||
| Conveyor speed | 300-2000 mm/min | |||||
| Auto-lubrication | Multi-lubricating mode can be selected; automatic or manual lubrication | |||||
| Cooling, process management and listed options | ||||||
| Cooling method | Forced-air cooling | Water-chiller cooling listed for nitrogen reflow | ||||
| KIC RPI Reflow Process Inspection System | Option listed in supplied material | |||||
| Nitrogen system (reserved) | N-suffix configuration listed with nitrogen sealed structure, pipe, N2 flow meter and water chiller | |||||
| Full nitrogen system | Listed with oxygen analyser (pipe type) added to the nitrogen-reserved equipment scope | |||||
| Nitrogen consumption | For standard 400 mm width: 300-1000 ppm O2, 10-20 m³/h; N2 consumption noted as 500-1000 ppm O2, 20-30 m³/h | |||||
| Central support | Option listed. Supplied material notes no mesh if the central-support system is selected. | |||||
| Dual-rail conveyor | D model: dual rail; front and rear rails fixed, two central adjustable PCB rails (listed width 300 mm × 2) | |||||
The PDF uses approximate dimensions and weights. Final equipment scope, local electrical conditions, nitrogen consumption, cooling, usable board envelope and acceptance criteria must be confirmed before quotation.
The SR table is an engineering reference. Temperature profile, cooling performance and production suitability require validation with the actual PCB assembly, solder paste and acceptance criteria.
The supplied material identifies D as the dual-rail configuration. Confirm board size per rail, loading pattern, capacity and rail layout before selecting it.
The product table lists nitrogen-reserved and full-nitrogen configurations as options. It must be included only after the process and installation scope are confirmed.
Yes. Please provide the current line information, PCB range, throughput, transport interfaces, available space and utilities for a technical review.
SA-800, SA-1000, SA-800D and SA-1000D. The SA family provides 8 or 10 upper/lower heating-zone configurations, with standard single-rail and listed dual-rail D-model paths.
The supplied SA Series table gives four model designations and separates standard rail configurations from D-model dual-rail versions. The family has 8 or 10 upper/lower heating zones, a listed two-zone upper cooling arrangement, chain + mesh board conveyance and a complete parameter table below.
SA-800 and SA-800D list 8 top + 8 bottom heating zones; SA-1000 and SA-1000D list 10 top + 10 bottom.
Standard versions list up to 400 mm PCB width, with 450 mm optional. D versions list dual rail at 250 mm × 2.
PID closed-loop control plus SSR drive, ±1°C control precision and two upper cooling zones are listed in the supplied material.
Open the Technology & Video Centre for supplied-equipment media and the technical evaluation route, then return here for SA-series values.
All figures below are transcribed from the supplied SA Series product table. The horizontal table can be scrolled on a phone.
| Parameter | SA-800 | SA-1000 | SA-800D | SA-1000D |
|---|---|---|---|---|
| Heating system | ||||
| Heating zones | 8 top / 8 bottom | 10 top / 10 bottom | 8 top / 8 bottom | 10 top / 10 bottom |
| Heating length | 3110 mm | 3892 mm | 3110 mm | 3892 mm |
| Cooling zones | 2 upper cooling zones (internal cool-air conversion) | |||
| Exhaust volume | 10 m³/min × 2 channels | |||
| Conveyor system | ||||
| Maximum PCB width | 400 mm (option: 450 mm) | 250 mm × 2 listed for dual rail | ||
| Conveyor direction | Left to right (option: right to left) | |||
| Fixed rail side | Front rail fixed (option: rear rail fixed) | Front and rear rails fixed; two central rails adjustable | ||
| Conveyor height | 900 ± 20 mm | |||
| PCB conveyor method | Chain + mesh (option: chain + central support; supplied material notes single-pin chain) | |||
| Component clearance | Top 30 mm / bottom 25 mm | |||
| Conveyor speed range | 300-2000 mm/min | |||
| Control system | ||||
| Power supply | 3 phase, 380 V, 50/60 Hz (optional: 3 phase, 220 V, 50/60 Hz) | |||
| Total power | 64 kW | 80 kW | 70 kW | 83 kW |
| Startup power | 30 kW | 36 kW | 32 kW | 38 kW |
| Normal power consumption | 10 kW | 11 kW | 11 kW | 12 kW |
| Warm-up time | Approx. 30 min | Approx. 35 min | ||
| Temperature control range | Room temperature to 300°C | |||
| Temperature control method | PID closed-loop control + SSR drive | |||
| Temperature control precision | ±1°C | |||
| PCB temperature deviation | ±1.5°C | |||
| Data storage | Process data and status storage for multiple production settings | |||
| Abnormal alarm | Abnormal temperature alarm (extra-high / extra-low temperature) | |||
| Colour tower | Three lights: yellow warm-up, green normal, red abnormal | |||
| General machine parameters | ||||
| Dimensions (L × W × H) | 5225 × 1430 × 1530 mm | 6005 × 1430 × 1530 mm | 5225 × 1680 × 1530 mm | 6005 × 1680 × 1530 mm |
| Approx. weight | 2300 kg | 2615 kg | 2645 kg | 3050 kg |
| Colour | Computer grey (final colour subject to technical agreement) | |||
| Rectifying plate material | Galvanized sheet | |||
| Listed option | ||||
| Dual-rail conveyor | D model: dual rail; rails 1 and 3 or 1 and 4 fixed; supplied table notes maximum PCB size 250 × 250 mm through two rails at the same time | |||
The PDF uses approximate dimensions and weights. Final equipment scope, local electrical conditions, rail layout, usable board envelope and acceptance criteria must be confirmed before quotation.
The SA table supports early model selection. It does not replace a project-specific check of PCB size, component clearance, product mix, profile, capacity, utilities and final line connection.
The supplied table lists SA-800 and SA-1000 as the standard model path, while SA-800D and SA-1000D are the listed dual-rail versions.
The supplied table lists 400 mm as the maximum PCB width and 450 mm as an option for the standard rail versions. Confirm the actual board and component clearances before quotation.
Yes. The parameter groups shown here cover the heating system, conveyor system, control system, general machine parameters and the listed dual-rail option from the supplied SA Series material.
Use this page to review real reference images and supplied video material, understand the function routes, and see how process evaluation is discussed before choosing an S, SR or SA model.
The product series pages contain the exact model tables. This page complements them with the working functions, supplied-document evaluation method and real equipment media that customers normally ask about during the first technical discussion.
S, SR and SA models are offered with model-specific 8, 10 or 12-zone routes. The detailed pages show the listed upper/lower-zone configurations, heating lengths and temperature-control components for each model.
Mesh and chain transport arrangements are shown in the supplied equipment material. Single-rail and listed dual-rail D versions must be matched to the board width, clearance and throughput requirement.
Cooling-zone counts, cooling path, exhaust and nitrogen-related routes differ by series and model. Confirm the selected table and project utilities rather than applying one configuration to all models.
Process selection starts with the PCB, components, solder paste and target profile. The supplied documentation presents a distributed thermocouple test approach; final profiling is validated with the customer board and agreed process window.
The supplied series tables list their respective control, alarm, recorder and optional configuration entries. Please use the selected-series page as the quotation baseline.
Infeed/outfeed direction, upstream and downstream equipment, electrical supply, exhaust route and installation space should be confirmed before a final layout is released.
The supplied technical document describes a comparison method using multiple thermocouple positions, a test board/net and a profiler. It is a project-review framework, not a blanket performance promise for every PCB or configuration.
| Evaluation item | What the supplied material describes | How it is used in a project review |
|---|---|---|
| Distributed temperature check | Multiple thermocouple measurement positions are used with a test plate/net to compare thermal distribution. | Compare the result against the required process window and the customer PCB profile. |
| Temperature-delta comparison | The document uses the measured temperature difference between positions as an indication of distribution consistency. | Review the result with the selected profile; a customer board and components remain the final validation basis. |
| Effective heating-length method | The document illustrates an effective-heating ratio based on active length versus total heating-section length. | Use it as a technical discussion input alongside conveyor speed, board mass and target throughput. |
| Final acceptance route | The selected oven model, options and process conditions define the valid scope. | Confirm configuration, utilities and the agreed acceptance criteria before shipment. |
The wording above is deliberately limited to the supplied reflow-oven technical material. It does not replace a customer-board profile or an agreed factory acceptance plan.
These images are from the supplied reflow-oven folder and show the actual equipment or line-reference material used for this website.
All six clips below are from the supplied material. They are visual reference only; use the selected series page and quotation configuration for any model-specific commitment.
Actual reflow-oven and conveyor reference footage.
Actual inside-equipment and mesh-belt view from the supplied video.
Actual internal-equipment, transport and cooling-area views from the supplied video. The original was web-compressed for page loading; the source clip remains unchanged.
Visual coin demonstration from the supplied video. It is not a quantified customer acceptance test.
Actual factory / dispatch-area reference footage from the supplied material.
Actual production-floor footage showing the reflow-oven equipment area.
After viewing the technology material, open the product family that best fits your target zone count and line requirement. Each link goes to a separate parameter-table page.
Full six-model S specification table with 8, 10 and 12-zone model paths.
Open S detailsFull six-model SR specification table, cooling and configuration entries.
Open SR detailsDedicated SA parameter table for single-rail and listed D model paths.
Open SA detailsNo. This page introduces the functions and real material across the supplied range. The exact standard scope, option list and utilities must be confirmed from the selected S, SR or SA table and final quotation.
Yes. The clips are suitable as equipment-reference material. Send the associated series page as well, so the customer can see the correct detailed parameter table.
Start with PCB dimensions, product mix, profile target, capacity, rail requirement, utilities and line layout. We then confirm the suitable series, model and options for the project.
Share PCB dimensions, process, target output, single/dual rail requirement and local utilities. We will help identify the suitable series and final model path.